Bangla CAT
back
to top

Key Specs

Gas Genset G3512H

Continuous Rating 1515 ekW / 1505 ekW @1.0pf

Fuel Type Natural Gas, Hydrogen Blend (up to 25%)

Maximum Electrical Efficiency 44.90%

Overview

1061 - 1515 kW Gas Generator

From natural gas to biogas, coal mine gases, or hydrogen fuel blends to support combined heat and power (CHP), emergency power, and local grid support applications, Caterpillar has a wide range of reliable gas power solutions.

 

BENEFITS & FEATURES


BENEFITS

Up to 25% hydrogen blended fuel option
Enables operation of up to 25% hydrogen blend (by volume) with pipeline natural gas fuel

Up to 15% savings on service
Extended maintenance intervals leading to lower service costs

Up to 20% lower lube oil consumption
Leading to lower service costs and extended maintenance intervals

 

FEATURES
 


Cat G3512H Gas Engine

  • Robust high speed block design provides prolonged life and lower owning operating costs
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen mixtures
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection


SR5 Generator

  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency


EMCP 4.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements


Emissions

  • Meets most worldwide emissions requirements down to 0.5 g/bhp-hr NOx level without aftertreatment


Proven System

  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available


Full Range of Attachments

  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation


Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

 

SPECIFICATIONS


Generator Set Specifications
Continuous Rating 1515 ekW / 1505 ekW @1.0pf
Fuel Type Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 44.90%
Frequency 50 / 60 Hz
RPM 1500 rpm
Engine Specifications
Engine Model G3512H
Displacement 3574 in³
Aspiration TA
Bore 6.7 in
Stroke 8.5 in
Governor Type ADEM A4
Generator Set Dimensions
Length 223 in
Width 76 in
Height 91 in
Dry Weight - Genset 31085 lb

Standard Equipment



Air Inlet

  • Package Mounted Air Cleaner with service indicator


Cooling

  • Jacket water and SCAC thermostats
  • 2nd Stage CAT Flange
  • ANSI Class 150 JW Connection
  • Engine driven pumps for jacket water and aftercooler cooling


Control Panels

  • Dedicated customer wiring terminals


Control Panel

  • EMCP4.3


Exhaust

  • Dry exhaust manifolds insulated and shielded
  • Center section cooled turbocharger with Cat flanged outlet


Generator

  • High efficiency low voltage Cat generator, permanent magnet excitation, digital regulation, IP23 water ingress protection, & form wound construction.


Starting/Charging

  • Electric Starter


General

  • Paint - Caterpillar Yellow except rails and radiators gloss black
  • Crankshaft vibration damper and guard

 

Optional Equipment



Air Inlet

  • Mounting brackets and piping
  • Air cleaner with precleaner


Control Panels

  • Remote annunciator


Circuit Breakers

  • Frame mounting circuit breaker orientation
  • 2500A 3-pole IEC rated circuit breakers
  • Rear Mounted Circuit Breaker
  • 3000A/3200A/4000A UL100% Rated Masterpact circuit breaker (60 Hz only)
  • LSI Long-Time, LSI-P Long-Time, LSIG Long-Time, LSIG-P Long-Time


Control Panel

  • Language Options
  • Cable Shroud Location
  • Engine failure relay
  • Discrete I/O module, 12 digital points, 8 'Form C' relay
  • 16 point/32 light annunciator with NFPA99-110/CSA282 configuration
  • Empty Upper Box Right/Left
  • Local Alarm module
  • Synchronization module
  • Cat Connect: Ethernet, satellite, or cell telematics
  • Local/Remote PC Monitoring
  • Right/Left/Rear Extension Box


Cooling

  • Remote radiator for JW and SCAC circuits
  • 220V (50Hz), 240V (60Hz), 480V (60Hz) JW heater


Exhaust

  • Flexible fitting [305mm x 305mm (12in. X 12in.)] w/ 12 bolt-flanges
  • 406mm (16in.) sparking-arresting muffler with companion flange
  • Exhaust expander [250mm-329mm (10in-12in)]
  • 305mm (12 in.) flange
  • Muffler options
  • Elbow exhaust


Fuel System

  • 1/2" NPT gas train conduit connectors
  • 3, 0-100kPag 4-20mA gas train pressure sensors
  • Fuel Filter
  • Gas knockdown regulators


General

  • Digital Diagnostic tool
  • US Aid emblem


Generator

  • Generator air filter
  • Manual voltage control
  • Cable access box
  • RTD Monitoring
  • Bearing temperature detectors

 

Governing System

  • ADEM A4 4-20mA (0-5V) speed input


Starting/Charging

  • Battery with cables and rack
  • 24V Starting motors
  • 20A, 24VDC battery charger
  • 45A, 24V charging alternator (requires engine driven pumps)
  • Jacket water heater


Grid Code Compliance

  • 60 Hz: USA
  • 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard